Your browser doesn't support javascript.
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters

Language
Document Type
Year range
1.
Front Public Health ; 10: 994712, 2022.
Article in English | MEDLINE | ID: covidwho-2099270

ABSTRACT

The severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) pandemic can be effectively controlled by rapid and accurate identification of SARS-CoV-2-infected cases through large-scale screening. Hypercube pooling polymerase chain reaction (PCR) is frequently used as a pooling technique because of its high speed and efficiency. We attempted to implement the hypercube pooling strategy and found it had a large quantization effect. This raised two questions: is hypercube pooling with edge = 3 actually the optimal strategy? If not, what is the best edge and dimension? We used a C++ program to calculate the expected number of PCR tests per patient for different values of prevalence, edge, and dimension. The results showed that every edge had a best performance range. Then, using C++ again, we created a program to calculate the optimal edge and dimension required for pooling samples when entering prevalence into our program. Our program will be provided as freeware in the hope that it can help governments fight the SARS-CoV-2 pandemic.


Subject(s)
COVID-19 , SARS-CoV-2 , Humans , SARS-CoV-2/genetics , COVID-19 Testing , COVID-19/diagnosis , Pandemics , Polymerase Chain Reaction
2.
Applied Sciences ; 11(22):10674, 2021.
Article in English | MDPI | ID: covidwho-1512089

ABSTRACT

Hypoxemia and obstructive sleep apnea (OSA) have been recognized as a threat to life. Nonetheless, information regarding the association between pre-dialytic pulse oximeter saturation (SpO2) level, OSA and mortality risks remains mysterious in patients with maintenance hemodialysis (MHD). Bioclinical characteristics and laboratory features were recorded at baseline. Pre-dialytic SpO2 was detected using a novel microchip LED oximetry, and the Epworth Sleepiness Scale (ESS) score greater than 10 indicated OSA. Non-adjusted and adjusted hazard ratios (aHRs) of all-cause and cardiovascular (CV) mortality were analyzed for pre-dialytic SpO2, OSA and potential risk factors. During 2152.8 patient-months of follow-up, SpO2 was associated with incremental risks of all-cause and CV death (HR: 0.90 (95% CI: 0.82–0.98) and 0.88 (95% CI: 0.80–0.98), respectively). The association between OSA and CV mortality was significant (HR: 3.19 (95% CI: 1.19–9.38). In the multivariate regression analysis, pre-dialytic SpO2 still had an increase in all-cause and CV death risk (HR: 0.88 (95% CI: 0.79–0.98), 0.82 (95% CI: 0.71–0.96), respectively). Considering the high prevalence of silent hypoxia in the post COVID-19 era, a lower pre-dialytic SpO2 level and severe OSA warn clinicians to assess potential CV risks. In light of clinical accessibility, the microchip LED oximetry could be developed as a wearable device within smartphone technologies and used as a routine screen tool for patient safety in the medical system.

SELECTION OF CITATIONS
SEARCH DETAIL